<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-11 23-13-01
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.10 MHz 4/5, 39 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz 3.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
5 kHz 77 kHz 4801 17,6422
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,3 dBr 6,42 dBr 7,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 1 23:12, 11.04.2025
RT
-
AF EON
87.6, 87.7, 90.2, 90.4, 90.6, 92.3, 95.3, 96.4, 97.3, 99.1, 100.7, 101.2, 101.6, 102.6, 103.1, 103.2, 103.3, 103.6, 104.1, 104.8, 106.7, 107.2, 107.3, 107.5, 107.9 MHz -
FM Scope Station: 103.10 MHz, signal: 4/5 (39 dBuV) Max at: 77 kHz MIN: 5 kHz % above 76 kHz: 17,6422 Acquired: 2025/04/11 23:11:57 Total samples: 4801 Equivalent time: 0:04:00 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 7,2 dBr MIN: 5,3 dBr AVE: 6,42 dBr % above 10,2 dBr: 0,0 Last value: 6,8 dBr (2025/04/11 23:11:57) Station: 103.10 MHz, signal: 3/5 (39 dBuV) 23:05 23:06 23:07 23:08 23:09 23:10 23:11 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality